Planck-dust-allsky

OGLE-2017-BLG-0329L: A Microlensing Binary Characterized with Dramatically Enhanced Precision Using Data from Space-based Observations

June 2018 • 2018ApJ...859...82H

Authors • Han, C. • Calchi Novati, S. • Udalski, A. • Lee, C. -U. • Gould, A. • Bozza, V. • Mróz, P. • Pietrukowicz, P. • Skowron, J. • Szymański, M. K. • Poleski, R. • Soszyński, I. • Kozłowski, S. • Ulaczyk, K. • Pawlak, M. • Rybicki, K. • Iwanek, P. • OGLE Collaboration • Albrow, M. D. • Chung, S. -J. • Hwang, K. -H. • Jung, Y. K. • Ryu, Y. -H. • Shin, I. -G. • Shvartzvald, Y. • Yee, J. C. • Zang, W. • Zhu, W. • Cha, S. -M. • Kim, D. -J. • Kim, H. -W. • Kim, S. -L. • Lee, D. -J. • Lee, Y. • Park, B. -G. • Pogge, R. W. • Kim, W. -T. • KMTNet Collaboration • Beichman, C. • Bryden, G. • Carey, S. • Gaudi, B. S. • Henderson, C. B. • Spitzer Team • Dominik, M. • Helling, C. • Hundertmark, M. • Jørgensen, U. G. • Longa-Peña, P. • Lowry, S. • Sajadian, S. • Burgdorf, M. J. • Campbell-White, J. • Ciceri, S. • Evans, D. F. • Haikala, L. K. • Hinse, T. C. • Rahvar, S. • Rabus, M. • Snodgrass, C. • MiNDSTEp Collaboration

Abstract • Mass measurements of gravitational microlenses require one to determine the microlens parallax π E, but precise π E measurement, in many cases, is hampered due to the subtlety of the microlens-parallax signal combined with the difficulty of distinguishing the signal from those induced by other higher-order effects. In this work, we present the analysis of the binary-lens event OGLE-2017-BLG-0329, for which π E is measured with a dramatically improved precision using additional data from space-based Spitzer observations. We find that while the parallax model based on the ground-based data cannot be distinguished from a zero-π E model at the 2σ level, the addition of the Spitzer data enables us to identify two classes of solutions, each composed of a pair of solutions according to the well-known ecliptic degeneracy. It is found that the space-based data reduce the measurement uncertainties of the north and east components of the microlens-parallax vector {{\boldsymbol{π }}}{{E}} by factors ∼18 and ∼4, respectively. With the measured microlens parallax combined with the angular Einstein radius measured from the resolved caustic crossings, we find that the lens is composed of a binary with component masses of either (M 1, M 2) ∼ (1.1, 0.8) M or ∼(0.4, 0.3) M according to the two solution classes. The first solution is significantly favored but the second cannot be securely ruled out based on the microlensing data alone. However, the degeneracy can be resolved from adaptive optics observations taken ∼10 years after the event.

Links


IPAC Authors
(alphabetical)

Fotina

Sebastiano Calchi Novati

Associate Scientist


Sean Carey

Senior Scientist